T5, T14D, T20C, T24C, T40
Blast Chiller/Shock Freezers
Service, Installation and Care Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of
damage! Inspect all components immediately. See page 2.
Blast Chillers/Shock Freezers
Effective Date August 2006
IMPORTANT INFORMATION
READ BEFORE USE
PLEASE SAVE THESE INSTRUCTIONS!
Przeglądanie stron 0
1 2 3 4 5 6 ... 43 44

Podsumowanie treści

Strona 1 - Blast Chiller/Shock Freezers

T5, T14D, T20C, T24C, T40 Blast Chiller/Shock FreezersService, Installation and Care ManualPlease read this manual completely before attempting to ins

Strona 2

5.1 STARTING UP THE APPLIANCE (only for T14D / T20C / T24C / T40)PRE HEATING FUNCTION OF COMPRESSOR SUPWhen power is initially supplied to the cabinet

Strona 3

IMPORTANT: work cycles and modes can only be selected when the appliance is ON (LED on push -button 6 o)IMPORTANT: The appliance will automatically

Strona 4 - 1. GENERAL DOCUMENTATION

• At the end of the chilling cycle, the appliance automatically switches to the set storage temperaturefor an indenite interval (like a standard stor

Strona 5 - 2. INSTALLATION

5.4 HARD BLAST CHILLING BY TEMPERATURE• Press push-button 3 (relative LED lights up), then press push-button 5 to select the temperature mode (LED

Strona 6

The time setting (in minutes) can be modied by means of push-buttons 74.1PUSH-BUTTONS:1.ON /OFF (STAND BY)2.SOFT BLAST CHILLING CYCLE (+38°F / +3°C)3

Strona 7

5.7 TIMED BLAST FREEZING• Press push-button 44.1PUSH-BUTTONS:1.ON /OFF (STAND BY)2.SOFT BLAST CHILLING CYCLE (+38°F / +3°C)3.HARD BLAST CHILLING CYCLE

Strona 8 - HACCP PROGRAM

6.1 DATE AND TIME SETTINGS : PUSH-BUTTON (5)Set the machine to ON 4.1PUSH-BUTTONS:1.ON /OFF (STAND BY)2.SOFT BLAST CHILLING CYCLE (+38°F / +3°C)3.HAR

Strona 9

6.5 DISPLAYING THE THREE LATEST HACCP ALARMS (PUSH-BUTTON 10)Set the machine to ON 4.1PUSH-BUTTONS:1.ON /OFF (STAND BY)2.SOFT BLAST CHILLING CYCLE (+

Strona 10 - 8. MAINTENANCE AND CLEANING

7. ALARM MANAGEMENT7.1 Storage of data/errorsThe appliance electronic controller is equipped with a system of acoustic and visual signals to indicate

Strona 11

Input SW2 (ALL 05) (door microswitch alarm)Cause: Input active for more than 5 minutes with appliance in start status. Door open (close door) Mic

Strona 12

CONTENTS1. GENERAL DOCUMENTATION1.1 General information page 51.2 Installation page 51.3 Transport and handling page 51.4 Unpack

Strona 13

Excessive temperature alarm (ALL 11)Cause: (only during storage) cell probe constantly detects a temperature greater than the sum of positive or

Strona 14

INFORMATION ON ALARMS:During alarms, the beeper is activated and the display shows the message “ALL xx”.The alarm message is alternated on the display

Strona 15

8. MAINTENANCE AND CLEANINGThe information and instructions given in this section address all persons operating the appliance:the user, the maintenanc

Strona 16 - 6. APPLIANCE FUNCTIONS

Delfield™®T5: Blast Chiller/Shock Freezervvvvvvv!vv

Strona 17

Delfield™®T14D: Blast Chiller/Shock Freezervvvvvvvv

Strona 18 - 7. ALARM MANAGEMENT

Delfield™®T20C: Blast Chiller/Shock Freezerby Delfield®38380™Sample PrintoutREFRIGERANT LINESELECTRICALDRAINDRAINREFRIGERANT LINESELECTRICALDRAINDRAIN

Strona 19

Delfield™®T24C: Blast Chiller/Shock Freezerby Delfield®38380™Sample PrintoutREFRIGERANT LINESDrainDrainELECTRICAL LINESREFRIGERANT LINESDrainDrainELEC

Strona 20

Delfield™®T40: Blast Chiller/Shock Freezerby Delfield®38380™Sample PrintoutREFRIGERANT & ELECTRICAL LINESDRAINDRAIN30”5.5”REFRIGERANT & ELECTR

Strona 21

Delfield™®T20C & T24C: Blast Chiller/Shock Freezer Remote Condensing Unit39.0039.0039.0039.00T20C/T24CDeleld Model#: T20-T24CURefrigerant 404ACom

Strona 22 - 8. MAINTENANCE AND CLEANING

Delfield™®T20C/T24CDeleld Model#: T20-T24CUWRefrigerant 404ACompressor and wiringCompressor and Capacity3 HP Compressor9,950 BTUH @ -40˚F, 85˚F inlet

Strona 23 - Delfield

6. APPLIANCE FUNCTIONS6.1 Date and time settings page 196.2 Ice cream surface hardening page 196.3 Muting the beeper and alarm reset

Strona 24

Delfield™®T40Deleld Model#: T40CURefrigerant 404ACompressor and wiringCompressor and Capacity6 HP Compressor24,150 BTUH @ -32˚F, 90 amb, 102.2 Cond:

Strona 25

Delfield™®T40CUW: Remote Water Cooled Condensing UnitT40Deleld Model#: T40CUWRefrigerant 404ACompressor and wiringCompressor and Capacity6 HP Compres

Strona 26

T5/T14D REFRIGERATION SYSTEM SCHEMATIC

Strona 27

9. WIRING DIAGRAMS

Strona 32

T40 RS Wall PanelSupplied Equipment List.T40 BaseT40 LS Wall PanelT40 Back PanelT40 Control BoxT40 Front Panel with DoorT40 Top PanelT40 Air Deection

Strona 33 - 9. WIRING DIAGRAMS

1. Position cabinet floor on a flat, level surface with the slotted end facing up.• Ensure the entryway is facing forward (gray plastic transition p

Strona 34

1.1. General information• This manual is an integral part of the product, providing all the information required to ensure correct installation, opera

Strona 35

4. Attach the right side panel to the mounting floor in the same manner as the other two panels. Lock the side locking cams on the inside bottom and s

Strona 36

8. Thread electrical from the inside of the unit through the supplied hole in the top. Do not cut another hole to thread electrical. 9. Thread electri

Strona 39

980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • (989) 773-7981 or (800) 733-8829 • Fax (888) 779-2040 • www.delfield.comDelfield reserves the r

Strona 40

2. INSTALLATION2.1 Data plate information• Check that the data specied on the plate correspond to the characteristics of the power supply (V, kW, Hz,

Strona 41

2.6 Condensate drainage connection For models T20C-T24C-T40 t a condensate water drainage hose with a minimum diameter of 1” . Provide a waste pipe

Strona 42

3.1 Shut-down procedures In the event of emergency, shut down the appliance by switching o power at the main panel, by means of a breaker or power d

Strona 43

4. DESCRIPTION OF THE VERTICAL CONTROL PANEL+38o0o+38oHARDoCHACCP PROGRAM65151121035a45b1478911213

Strona 44 - DMCONVOCHILL 06/07

4.1PUSH-BUTTONS:1.ON /OFF (STAND BY)2.SOFT BLAST CHILLING CYCLE (+38°F / +3°C)3.HARD BLAST CHILLING CYCLE (+38°F / +3°C)4.BLAST FREEZING CYCLE (0°F /

Komentarze do niniejszej Instrukcji